    Now working on getting a 991 up and running. I thought it would be easy since it seemed to pressurize and I thought I tested the jet and just installed a mantle. Turns out it is going to be more interesting. No fuel comes out of the jet. Turns out the pricker needle is stuck in the jet. It could very well be due to some mishandling from my part. I did a double priming as this is sometimes needed and I didn't want to soot things up and flare up indoors. I might also have turned the valve when I'm not supposed to.
    Anyway now I would like to get the jet cleared and try to avoid any mishandling in the future. I might have made a similar mistake on my 1020. I just saw that the old jet also had the needle stuck in it (I replaced the jet with a new one).
     
  2. podbros

    podbros United Kingdom Subscriber

    Offline
    Joined:
    Dec 27, 2015
    Messages:
    4,092
    Location:
    .. next to the Chester & Birkenhead Rlwy
    Hi @kephart

    there is a thread about using Alum which dissolves the Steel but not Brass?
    here is a screenshot of the thread ;

    IMG_9355.jpeg

    when you find it there are more images which look encouraging
    cheers
    pb
     
  3. kephart Sweden

    Offline
    Joined:
    Jul 5, 2026
    Messages:
    9
    Location:
    Stockholm, Sweden
    I tried soaking it in citric acid and it seemed to work. At least I can see through it. I'm thinking it probably dissolved the carbon soot that made it stuck.
     
  4. kephart Sweden

    Offline
    Joined:
    Jul 5, 2026
    Messages:
    9
    Location:
    Stockholm, Sweden
    The fettling of this lamp turned out to a be a lot harder than I thought. When the jet was cleaned it still didn't pressurize. I suspected a bad tank lid gasket so I decided to make a new one from a retro lemonade bottle. It seemed to work and I tested it on a working Primus 1020 which has the same dimensions. I also wanted to check the pump leather but it again turned out to work well on the 1020. I now had my suspicions about the NRV. I had to push hard and add some kerosene in the pump tube to get it unstuck. It didn't feel quite right pumping either.
    I tried to remove it with the correct Primus-tool and it unscrewed easily, but didn't come out. A lot of wiggling and mild prodding with some steelwire finally made it fall out. I unscrewed it and inspected the pip. It looked a bit short and was made of cork from what I can tell. I decided to change it, but would like to fix it at some point, but I had no Viton-rubber at hand and no nitrile either as far as I know, but maybe I could have scavenged some from an old lawnmover fuel hose or something. Now finally it sprayed fuel out of the jet. Time to test it. A lot of burning from odd places, spilled fuel perhaps? A bit surprised by the amount of burning on the lid.
    20260806_161832.jpg 20260806_161936.jpg

    Finally it shines strong:
    20260806_162315.jpg
     
  5. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,842
    Location:
    Shetland Islands UK..
  6. kephart Sweden

    Offline
    Joined:
    Jul 5, 2026
    Messages:
    9
    Location:
    Stockholm, Sweden
    I think I know what the "burning hat" was about.
    Since the pricker needle is gone it is not a good idea to pump it up before priming is done. It sprays unburnt fuel all over the place. I might need to get a new pricker.
     
  7. Nils Stephenson

    Nils Stephenson Founder Member

    Offline
    Joined:
    Sep 9, 2010
    Messages:
    3,399
    Location:
    Copenhagen, Denmark
    The pricker is not meant to close off the jet, it is only for cleaning. You should not start pumping until the lamp is fully pre-heated.
     
  8. kephart Sweden

    Offline
    Joined:
    Jul 5, 2026
    Messages:
    9
    Location:
    Stockholm, Sweden
    I see, but now the valve does not seem to block the flow much at all. Maybe i need to adjust it.
     
  9. Nils Stephenson

    Nils Stephenson Founder Member

    Offline
    Joined:
    Sep 9, 2010
    Messages:
    3,399
    Location:
    Copenhagen, Denmark
    That's the whole point, there is no valve in a 991. All it is is a mechanism to raise and lower the cleaning needle. The lamp is not designed to hold pressure while it is not being used.
     