AGM 3016 in action

Discussion in 'Lamp Action Gallery' started by Darryl Durdin, Aug 14, 2022.

  1. Darryl Durdin

    Darryl Durdin Australia Subscriber

    Offline
    Joined:
    Dec 11, 2018
    Messages:
    1,650
    Location:
    Whyalla. South Australia. Australia
    Hi fellas this is my AGM 3016, runs on shellite. It a very bright lantern. It needs a fuel cap seal but all is good A9091142-8945-4D7C-AFFD-5E886C8D1E70.jpeg 88B3970F-EA59-461F-B692-10B5BF580B60.jpeg 3E741E62-435D-4485-9BCD-8FDBD4FFBA59.jpeg 195DA9C1-725F-4E60-AFCA-D5CE8CED5539.jpeg
     
  2. ColinG United Kingdom

    Offline
    Joined:
    Oct 2, 2017
    Messages:
    4,816
    Very nice! I particularly like the burgundy colour. Some early Vapalux models use the same colour. Nice!
     
  3. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,886
    Location:
    Shetland Islands UK..
    A good find.:thumbup:
     
  4. Norman

    Norman United States Subscriber

    Offline
    Joined:
    Jul 1, 2011
    Messages:
    747
    Location:
    Spokane, WA
    @Darryl Durdin

    If you are interested in converting your 3016 to kerosene it is pretty easy to do.
    If you use the jet from a Coleman 201 along with the pricker rod and wire it will run very well on kerosene.

    IMG_20220801_164342710.jpg IMG_20220801_164357998_HDR.jpg IMG_20220801_164504302_HDR.jpg

    Granted I have the wrong sized mantle but it will indeed work.

    There are way too many purist who get upset about this type of conversion.
    If interested PT me and we can discuss what needs to be done to make this work.
     
  5. Henry Plews

    Henry Plews Subscriber

    Offline
    Joined:
    Jun 23, 2014
    Messages:
    3,067
    Location:
    North Yorkshire
    Hi Darryl, I also like the 3016, I've nothing against Colemans of a similar size / candle power but the shape of the 3016 fount is more pleasing to my eye.

    At the moment, I've a Coleman 21A on my example but I know it will easily handle a #99 (or Peerless equivalent).
     
  6. Darryl Durdin

    Darryl Durdin Australia Subscriber

    Offline
    Joined:
    Dec 11, 2018
    Messages:
    1,650
    Location:
    Whyalla. South Australia. Australia
    @Henry Plews @Norman ,
    Hi fellas I have an issue with the AGM. I dismantled and cleaned everything, I put a Coleman generator (shellite) / Coleman fuel. So as to be compatible. My issue is that I have a slow air leak. I’ve done the dunk test a number of times as it had small leaks . New fuel seal cleaned ever part.
    Air leak at the fuel pick up at the font. Unscrewed removed the pick up cleaned everything even the brass mesh. Used a Lo loctite thread sealer it had still leaking, removed cleaned and re set with Teflon tape no leaks. The pump works fine, the NRV dose not leak. Yet it lights up it’s makes a nice his it’s going great but 15 minutes or so it’s lost pressure and will go out. Am I missing something. I haven’t given up yet, I’ll be doing the full system check again when I can.
    Any advice is much appreciated
    Thanks fellas
     
  7. Norman

    Norman United States Subscriber

    Offline
    Joined:
    Jul 1, 2011
    Messages:
    747
    Location:
    Spokane, WA
    @Darryl Durdin

    I have several AGM 3016 lanterns and there is one that was having the same problem of loosing or leaking air.
    The preheater side of the lantern wasn't working and this is ware the leak was coming from.
    I had to block the preheater side. I tried soldering it but the solder melted and the air leak started up again.
    This time around I used J B Weld which solved the problem and I've had no leak since.
    Granted you will have to use a preheater cup to warm up the generator but it is working quite well now.
    I hope this information is helpful.

    Cheers,
    Norman
     
  8. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,886
    Location:
    Shetland Islands UK..
     
  9. Francisc Masec Netherlands

    Offline
    Joined:
    Jul 16, 2019
    Messages:
    195
    Location:
    Sweden
    @Darryl Durdin it is possible that the valve doesn't cut entirely using the air from the tank when is max open and it continue comming air/fuel instead of just fuel from the tank? ( i don't have any AGM lamp, I'm just guessing based on my imagination and on the fact that you fixed all the leaks and you don't see any bubbles).
    Cheers,
    Francisc
     